preLink®

The preLink® cabling system is an all-purpose cabling solution for IT, building automation and industry. It is a solution that can be used for all applications equally well. All preLink® connectors, sockets, and the new PCB sockets have one thing in common: they can all be connected in seconds using the preLink termination block. The coherent heart of the system.


preLink termination.jpg

Series Highlights

All-purpose cabling solution for IT, building automation and industry
Connected in seconds using the preLink termination block
Conformity with standards
Compatible with wide range of profiles
Independent of the surrounding environment
Pre-assembled and on-site assembly

Filter

Products 85

preLink RJ45 plug, IP20 Cat.6A
Connectors

preLink RJ45 plug, IP20 Cat.6A

Article No.: 20 82 101 0010

Connector RJ45preLink® IDC insulation displacement terminationMaleContacts: 8Degree of protection: IP20

HanPP V14 preLink RJ45 plug 8p met.
Connectors

HanPP V14 preLink RJ45 plug 8p met.

Article No.: 20 82 104 0001

Connector AIDA compliantpreLink® IDC insulation displacement terminationMaleContacts: 8Material: Zinc die-castNickel platedDegree of protection: IP65, IP67

preLink PCB jack THR
PCB jack

preLink PCB jack THR

Article No.: 20 82 007 1100

THR

preLink M12 plug D-coded 4-pole Cat.5
Cable connector

preLink M12 plug D-coded 4-pole Cat.5

Article No.: 20 82 005 0001

StraightMaleD-codingpreLink® IDC insulation displacement terminationContacts: 4Conductor cross-section: 0.1 ... 0.12 mm² 0.22 ... 0.32 mm²Screw mounted housingZinc die-castScrew lockingDegree of protection: IP65, IP67

preLink RJ45 plug, AWG22/24, IP20 Cat.6A
Connectors

preLink RJ45 plug, AWG22/24, IP20 Cat.6A

Article No.: 20 82 101 0012

Connector RJ45preLink® IDC insulation displacement terminationMaleContacts: 8Degree of protection: IP20

preLink RJ45 Keystone module empty
Connectors

preLink RJ45 Keystone module empty

Article No.: 20 82 500 0001

Female modulepreLink® IDC insulation displacement terminationSize: Keystone version

preLink RJ45 plug, IP20 Cat.6A L-0°
New
Connectors

preLink RJ45 plug, IP20 Cat.6A L-0°

Article No.: 20 82 101 0020

Connector RJ45, StraightpreLink® IDC insulation displacement terminationMaleContacts: 8Degree of protection: IP20

preLink RJ45 Jack HIFF Set AWG 26/27
Connectors

preLink RJ45 Jack HIFF Set AWG 26/27

Article No.: 20 82 001 0002

Female modulepreLink® IDC insulation displacement terminationSize: HIFF versionConductor cross-section: 0.1 ... 0.12 mm²

preLink M12 plug X-coded 8-pole Cat.6A
Cable connector

preLink M12 plug X-coded 8-pole Cat.6A

Article No.: 20 82 005 0002

StraightMaleX-codingpreLink® IDC insulation displacement terminationContacts: 8Conductor cross-section: 0.1 ... 0.12 mm² 0.22 ... 0.32 mm²Screw mounted housingZinc die-castScrew lockingDegree of protection: IP65, IP67

preLink RJ45 HIFF module empty
Connectors

preLink RJ45 HIFF module empty

Article No.: 20 82 000 0002

Female modulepreLink® IDC insulation displacement terminationSize: HIFF version

preLink M12 housing empty
Screw mounted housing

preLink M12 housing empty

Article No.: 20 82 000 1210

Screw lockingMaterial (hood/housing): Zinc die-castDegree of protection: IP65, IP67

preLink M12 plug-in module 4-pole Cat.5
Connectors

preLink M12 plug-in module 4-pole Cat.5

Article No.: 20 82 005 1214

preLink® IDC insulation displacement terminationMaleZinc die-cast, nickel-platedContacts: 4Conductor cross-section: 0.1 ... 0.12 mm² 0.22 ... 0.32 mm²

preLink RJ45 Jack HIFF Set AWG 22/24
Connectors

preLink RJ45 Jack HIFF Set AWG 22/24

Article No.: 20 82 001 0001

Female modulepreLink® IDC insulation displacement terminationSize: HIFF versionConductor cross-section: 0.22 ... 0.32 mm²

preLink RJ45 Keystoneset AWG22/23
Connectors

preLink RJ45 Keystoneset AWG22/23

Article No.: 20 82 501 0001

Female modulepreLink® IDC insulation displacement terminationSize: Keystone versionConductor cross-section: 0.22 ... 0.32 mm²

preLink RJ45 plug, IP20 Cat.6A L-90°
New
Connectors

preLink RJ45 plug, IP20 Cat.6A L-90°

Article No.: 20 82 101 0021

Connector RJ45, 90° angledpreLink® IDC insulation displacement terminationMaleContacts: 8Degree of protection: IP20

preLink RJ45 plug, IP20 Cat.6A L-35°
New
Connectors

preLink RJ45 plug, IP20 Cat.6A L-35°

Article No.: 20 82 101 0022

Connector RJ45, 35° angledpreLink® IDC insulation displacement terminationMaleContacts: 8Degree of protection: IP20

preLink M12-D cable jack 4-pole Cat.5
Cable connector, Panel feed through

preLink M12-D cable jack 4-pole Cat.5

Article No.: 20 82 005 2001

for rear mountingFemaleD-codingpreLink® IDC insulation displacement terminationContacts: 4Conductor cross-section: 0.1 ... 0.12 mm² 0.22 ... 0.32 mm²Zinc die-castScrew locking, PushPullDegree of protection: IP65, IP67

preLink M12-X cable jack 8-pole Cat.6A
Cable connector, Panel feed through

preLink M12-X cable jack 8-pole Cat.6A

Article No.: 20 82 006 2001

for rear mounting, StraightFemaleX-codingpreLink® IDC insulation displacement terminationContacts: 8Conductor cross-section: 0.1 ... 0.12 mm² 0.22 ... 0.32 mm²Zinc die-castScrew locking, PushPullDegree of protection: IP65, IP67

preLink M12 plug-in module 8-pole
Connectors

preLink M12 plug-in module 8-pole

Article No.: 20 82 006 1218

preLink® IDC insulation displacement terminationMaleZinc die-cast, nickel-platedContacts: 8Conductor cross-section: 0.1 ... 0.12 mm² 0.22 ... 0.32 mm²

Han 3A RJ45 preLink plug insert
Connectors

Han 3A RJ45 preLink plug insert

Article No.: 20 82 002 0001

ConnectorpreLink® IDC insulation displacement terminationMaleSize: 3 AContacts: 8

20 (of 85)

preLink® Ethernet cabling system


preLink portfolio

A unique functional feature of the preLink® system, not available elsewhere on the market, is the separation of cable and connector into two separate units. The cable and connector previously had an attached, permanent connection. Previously, crimp contacts or insulation displacement contacts could be connected only once. Now, the preLink is divided into two separable units. The first unit consists of connectors, sockets, couplings, or PCB terminals that have an identical fixture for holding the preLink termination block, which is the second unit and the heart of the system.

  • Consistent use of cabling for machinery, plant and IT

  • Usable for all Ethernet-based automation profiles

  • Robust 4-core cabling for Fast Ethernet

  • Future-proof 8-core cabling for Gigabit Ethernet and more

  • Integrated performance according Category 6A up to 500MHz

  • Suitable for Ethernet Transmission of 100Mbit/s, Gigabit and 10GBit/s

  • Easy in maintenance, adjustment and upgrade of the network

  • IP20/30, protected environment, switching cabinet

  • IP65/67, industrial environment

  • IP65/67, outdoor area and special applications

  • Alternative to on-site assembly

  • Quickly applied or exchanged

  • Connection tested ex-works

  • Reliable assembly with preLink® tool

  • Quick and simple

  • Constant across all connector types

The connection block offers space for up to eight wires, which can be shortened and connected on site in a single operation. The field-assembled cable now fits into every preLink component and can be inserted, removed or replaced at any time. Cables and connectors can be replaced independently of each other or installed separately.

This is particularly helpful when using pre-assembled cables. Data cables with termination blocks also fit through tight spaces and can be connected in seconds. This makes work considerably easier and saves time. In addition, worn cables can be easily replaced independently of the connector on moving devices, which further reduces operating costs.

The important benefit is the absolute process reliability of the installation. The system is error resistant and its unchanging installation process delivers continuous high performance and long-term stability. This is guaranteed by the exact match between the preLink® assembly tool and preLink® termination blocks.

Another big advantage of this technique is the relative assembly ease when compared to crimping and IDC. The wire strands are threaded only once through the marked openings in the termination block. They are then shortened and connected in one step using the corresponding tool. The insertion into the connector is so easy that even unskilled personnel can carry out the cabling work safely and reliably after brief training.

More solutions and ressources


Knowledge


Engineering Data & Services


CAD data, product data manager, distributors availability, free samples & more.

Engineering data icons

Discover the HARTING Engineerng Data & Services to support your projekt as best as possible. For each product in our digital catalogue you will find further engineering data & services:

More

  • CAD data, data sheets and type sheets

  • Product selectors with multiple attributes

  • Individually data packages

  • Configuration and customization

  • Individual notes and deratings

  • Free sample service